From 2D area to out of system

classic Classic list List threaded Threaded
2 messages Options
Reply | Threaded
Open this post in threaded view
|

From 2D area to out of system

Anuradha Rout
Hello everybody
I'm having troubles trying to model a sewer pipe, that collects the water that flows from the river into the sewage system.

In particular i would like to let some water, that propagates inside my 2D area, go to a storage area (or out of system) through a pipe or a culvert. Is that somehow possible?

i tryed the coordi-culvert method but it helps only if the water goes within the same 2D area.

thank you very much :)
Reply | Threaded
Open this post in threaded view
|

Re: From 2D area to out of system

Luis Partida
You can try extending your mesh to a region that does not impact your study area and coordi-culvert  the outfall pipe to that region to evaluate the volume/flow leaving the system which then you can use the output DSS to enter into a separate model entirely. Multiple meshes may work but im trying to visualize your scenario....an image may help guide better advice